Table of Contents

Preparatory Steps
Remove
Install
Finishing Steps



Preparatory Steps

TOC
 WARNING 

Batteries can emit explosive gases. To reduce the possibility of personal injury, always ventilate the compartment before servicing the batteries. To reduce the possibility of arcing, remove the negative (-) battery cable first and attach the negative (-) battery cable last.
  • Disconnect the batteries. Refer to the OEM service manual.


SMALL | MEDIUM | LARGE




Remove

TOC

Remove the electrical connections from the starting motor.



SMALL | MEDIUM | LARGE
   

Remove the three capscrews, starting motor, and starting motor spacer (if used).



SMALL | MEDIUM | LARGE
   




Install

TOC
 CAUTION 

Make sure to use the same thickness of starting motor spacer (if used) as the one removed to install the starting motor to prevent engine or starting motor damage.

Install the starting motor and the three capscrews.

Tighten the capscrews.

Torque Value:  176  n.m  [130 ft-lb]

Install and tighten the electrical connections to the starting motor.





SMALL | MEDIUM | LARGE
   




Finishing Steps

TOC
 WARNING 

Batteries can emit explosive gases. To reduce the possibility of personal injury, always ventilate the compartment before servicing the batteries. To reduce the possibility of arcing, remove the negative (-) battery cable first and attach the negative (-) battery cable last.
  • Connect the batteries. Refer to the OEM service manual.


SMALL | MEDIUM | LARGE


Last Modified:  31-Oct-2011